Commercial & industrial clients only · Brisbane · Gold Coast · Sunshine Coast · Toowoomba24/7 priority call-out for clientsFire client login →

Electrical · South East Queensland

RCD and safety switch testing

Safety switches only protect people if they trip fast enough. We push-button test and trip-time test the RCDs across your site and log every result.

Electrical Safety Regulation 2026 (Qld)

Services we provide

  • Push-button (user) testing
  • Operating-time (trip-time) testing
  • RCD schedule and labelling checks
  • Faulty RCD identification and replacement
  • A test record for every RCD

Why it matters

Queensland's Electrical Safety Regulation 2026 sets testing intervals for safety switches in workplaces, depending on the class of work and whether the safety switch is fixed or portable.

Regularly tested safety switches also matter for test and tag — in office and service work, equipment protected by a tested safety switch is treated differently.

Queensland safety switch testing intervals

Class of workSafety switchPush-button testOperating-time test
ConstructionFixed1 month12 months
ConstructionPortableDaily or before each use3 months
ManufacturingFixed6 months12 months
OfficeFixed6 months2 years
OfficePortable3 months2 years
Service (other than cleaning)Fixed or portable6 months2 years

WorkSafe Queensland safety switch testing intervals under the Electrical Safety Regulation 2026.

Pair it with

ElectricalTest & Tag

Book RCD testing and test and tag together and you'll get one visit and one set of results.

→

How it works

From first visit to filed certificate

  1. Free onsite assessment

    We walk the site, list every fire and electrical asset, and check where your records are up to.

  2. One quote, one schedule

    A single proposal covering both trades, with a service calendar built around your operations.

  3. Service, test and tag

    Technicians carry out the work to the relevant Australian Standards, with minimal disruption to your site.

  4. Reports, ready for audits

    Fire certificates and defect quotes land in your customer portal; electrical results and registers come straight to you.

FAQ

RCD / Safety Switch Testing: common questions

Can't see your question? Call 07 3916 4344 and talk to the team.

Will RCD testing cut the power?

Trip-time testing briefly cuts power to each protected circuit. We plan the order and timing with you to keep disruption low.

How often do safety switches need testing?

For fixed safety switches in office work, a push-button test every six months and an operating-time test every two years. Construction, manufacturing and portable devices are tested more often — see the table above.

What if an RCD fails?

We record it and replace it, so the circuit isn't left unprotected.

Free onsite quote

Get a free onsite quote

Fire protection, electrical, or both — tell us about your site and we'll arrange a free onsite assessment and one clear quote.

  • Call the team07 3916 4344
  • Email the teaminfo@hsfs.au
  • Office34 Millennium Place, Tingalpa QLD 4173
  • Business detailsABN 90 694 693 975
    QBCC Lic 15584545 · Hot Shot Fire Services Pty Ltd, licensed under the QBCC Act
    Electrical Contractor Lic 89637

24/7 priority call-out is available to existing Hot Shots clients in every region we cover, including Toowoomba (a call-out fee applies). For a fire or any life-threatening emergency, always call 000 first.

Request a free onsite quote

Takes about a minute. No obligation.

What do you need?

Commercial and industrial sites only. We'll reply to arrange a time to visit.

Thanks — your request is in. It has gone straight to our team at info@hsfs.au and we'll be in touch to arrange a time to visit. Urgent? Call 07 3916 4344.This is a preview, so nothing was sent. On the live website this request goes straight to info@hsfs.au.